Choose the wire and type the voltage, current and distance. The calculator gives the volts lost on the way, the voltage the load actually gets, and the gauge that keeps the loss small.
The worked example is a made-up 100 ft feed carrying 16 A to a garden shed on 12 AWG copper. Nothing you type leaves this browser.
Loading the calculator. If nothing appears, turn on JavaScript.
Length is one way, from the panel or source to the load. Current is what the load actually draws.
Enrichment · STEM ExplorationsFree
Resistance of the wire times the current.
A wire's resistance grows with its length and shrinks with its cross-section, measured in circular mils. The standard estimate is voltage drop = 2 × K × current × one-way length ÷ circular mils for single-phase and DC (current goes out and back), or √3 × K × current × length ÷ circular mils for three-phase. K is about 12.9 ohm-circular mils per foot for copper and 21.2 for aluminium at 75°C.
The National Electrical Code suggests, in informational notes, no more than 3% drop on a branch circuit and 5% overall; these are recommendations for performance, not the rules that make a circuit safe. The wire must be rated for the current, protected by the right breaker and installed to code. Electrical work needs a qualified electrician and local permits.
The worked example is made up. This is a learning estimate, not an electrical design; have a qualified electrician plan and install wiring. Your figures stay in this browser. Support: team@caveatacademic.com.